Product Details
Place of Origin: China Mainland
Brand Name: Tankii
Certification: ISO9001
Model Number: K
Payment & Shipping Terms
Minimum Order Quantity: Negotiable
Price: Negotiation
Packaging Details: Standard exoprt package in carton box or wooden case
Delivery Time: 5~20 days as per order qty
Payment Terms: T/T, Paypal, Western Union, MoneyGram,
Supply Ability: 1000Ton per year
Standard: |
ANSI, IEC584 |
Application: |
Thermocouple Sensor, MI Cable |
Tolerance: |
IEC 60584 Class 1 |
Diameter: |
Customized |
Delivery Time: |
5~10 Days After Getting The Payment |
Item: |
First Class Coiled Type E / N Thermocouple Wire 1.29mm 1.5mm |
Standard: |
ANSI, IEC584 |
Application: |
Thermocouple Sensor, MI Cable |
Tolerance: |
IEC 60584 Class 1 |
Diameter: |
Customized |
Delivery Time: |
5~10 Days After Getting The Payment |
Item: |
First Class Coiled Type E / N Thermocouple Wire 1.29mm 1.5mm |
First Class Coiled Type E / N Thermocouple Wire 1.29mm 1.5mm
Thermocouple wire allows temperatures to be measured electronically. A typical thermocouple construction consists of a pair of dissimilar metals that are electrically joined together at the sensing point and connected to a voltage measuring instrument at the other end. When one junction is hotter than the other, a thermal “electromotive” force (in millivolts) is produced that is roughly proportional to the difference in temperature between the hot and cold junctions.
First Class Coiled Type E / N Thermocouple Wire 1.29mm 1.5mm
Shanghai Tankii Thermocouple wire's Characteristics:
The thermocouple wires have excellent performance and are extensively used in the temperature measurement and control in different fields, such as metallurgy, chemical industry, petroleum industry, machinery-electric industry, energy industry, agriculture and military industry.
Tankii products conform to the standards of IEC584 -1 and 2.
Thermocouple type and index |
Measurement Range ℃ |
|
Type |
Index |
|
|
B | 600~1700 |
|
R | 0~1600 |
|
S | 0~1600 |
|
K | -200~1300 |
|
E | -200~900 |
|
J | -40~750 |
|
T | -200~350 |
|
N | -200~1300 |
The allowable grade and Tolerance are obtained at 0℃
Thermocouple |
Grade |
Temperature range |
Allowable Tolerance /℃ |
Type B | Ⅱ | 600~1700 | ±0.25% t |
Ⅲ | 600~800 | ±4 | |
800~1700 | ±0.5%t | ||
Type R(S) | Ⅰ | 0~1100 | ±1 |
1100~1600 | ±[1+(t-1100) ×0.3%] | ||
Ⅱ | 0~600 | ±1.5 | |
600~1600 | ±0.25% t | ||
Type K and Type N | Ⅰ | -40~1100 | ±1.5℃ or ±0.4%t |
Ⅱ | -40~1300 | ±2.5℃ or ±0.75%t | |
Ⅲ | -200~40 | ±2.5℃ or ±1.5%t | |
Type E | Ⅰ | -40~1100 | ±1.5℃ or ±0.4%t |
Ⅱ | -40~1300 | ±2.5℃ or ±0.75%t | |
Ⅲ | -200~40 | ±2.5℃ or ±1.5%t | |
Type J | Ⅰ | -40~750 | ±1.5℃ or ±0.4%t |
Ⅱ | -40~750 | ±2.5℃ or ±0.75%t | |
Type T | Ⅰ | -40~350 | ±0.5℃ or ±0.4%t |
Ⅱ | -40~350 | ±1.0℃ or ±0.75%t | |
Ⅲ | -200~40 | ±1.0℃ or ±1.5%t |